banner
Home » Knowledge » Content
Product Categories

IP Strong water spray test

- Mar 30, 2018 -

(6) IPX 6

Method name: Strong water spray test;

Test equipment: inner diameter of spray nozzle is 12.5 mm

Test conditions: as above 100 L/min (6000 L/h)

Test time: calculated according to the surface area of the shell of the tested sample, 1 min per square meter (excluding installation area) at least 3 min