banner
Home » Knowledge » Content
Product Categories

IP splash test

- Mar 30, 2018 -

(4) IPX 4

Method name: splash test

experiment method:

a. Pendulum tube type splash test

Test equipment and specimen placement: Same as in paragraph a of IPX 3 above;

Test conditions: Except for the following conditions, they are the same as those of the above IPX 3 section a; the water spray area is sprayed by the water spray hole in the 90° arc section on both sides of the midpoint of the pendulum pipe. The sample was placed in the center of a semi-circular tube. The oscillating tube oscillates 180° on both sides of the vertical, totaling about 360°. Each swing (2×360°) about 12s

Test time: Same as above for IPX 3 (ie 10 min).

b. Sprinkler-type splash test Test equipment and specimen placement: Same as in paragraph b of IPX 3 above;

Test conditions: remove the baffle with balance weights from the equipment, and the rest are the same as those of the above IPX 3 b;

Test time: the same as the above IPX 3 b, that is, according to the surface area of the shell of the tested sample, 1 min per square meter (excluding the installation area) at least 5 min